Since 1955, Gaco Western has been manufacturing exceptional waterproofing and insulating products. This family owned company was built on three fundamental principles: superior products; sold by experts; at competitive prices. Today, Gaco Western coatings and spray foam insulation cover millions of square feet of commercial and residential buildings around the world, earning a reputation and trust in the construction industry as a producer of top-quality waterproof coatings, sealers, primers and insulation products.
Gaco Western WallFoam 183M is an HFC blown (zero ozone-depleting) liquid spray system that cures to a medium-density rigid polyurethane insulation material. Gaco WallFoam 183M contains polyols derived from naturally renewable oils, post-consumer recycled plastics, and pre-consumer recycled materials. Gaco WallFoam 183M does not contain CFC’s, HCFC’s or other gases harmful to the environment. This system can be sprayed on clean, dry substrates down to 35°F (2°C). Gaco WallFoam 183M is a class I fire rated foam that meets the requirements of ICC-ES AC377 Acceptance Criteria for Foam Plastic Insulation. Gaco WallFoam183M meets the requirements of AC377 Appendix X for use in attic and crawl spaces.
To ensure optimum performance, a minimum pass thickness of 3/4” (1.9 cm) is recommended with the maximum not to exceed 2” (5.1 cm) per pass. For typical equipment settings, consult Gaco Western’s GacoFoam Spray Guide.
PROPERTY |
TEST TEMPERATURE |
ASTM TEST |
UNIT |
VALUE |
|
Nominal Density (Sprayed In Place): |
77°F (25°C) |
D-1622-03 |
lbs/ft3 |
1.8 - 2.2 |
|
R-Value (Initial) |
75°F (23.9°C) |
|
R at 1” |
6.7 |
|
R-Value (Aged) *See Note Below |
75°F (23.9°C) *See Note Below |
C-518 |
R at 1” |
Pending |
|
Compressive Strength (Parallel to Rise): |
77°F (25°C) |
D-1621-04a |
psi |
32 |
|
Tensile Strength: |
77°F (25°C) |
D-1623 |
psi |
64 |
|
Water Absorption: |
77°F (25°C) |
|
% |
0.45 |
|
Water Vapor Transmission: |
77°F (25°C) |
E-96-05 |
perm-in |
Pending |
|
Dimensional Stability (7 Days): |
158°F (70°C) / 95% RH |
D-2126-99 |
% Dimen. change |
4.7 |
|
Recommended Service Temperature Range: |
77°F (25°C) |
|
°F / °C |
-40°F to 200°F |
|
Closed Cell Content: |
77°F (25°C) |
D-6226-05 |
% |
97.8 |
|
Air Permeance @ 75Pa (Infiltration/Exfiltration) |
Air Permeance @ 75Pa (Infiltration/Exfiltration) |
E-283-04 |
L/s/m2 |
0.000 / 0.000 (@ 1” thickness) |
* NOTE: Federal Trade Commission regulations published in the Federal Register 16 CFR Part 460 require that R value testing of polyurethane foam insulation must be conducted on aged samples at a 75°F mean test temperature. Failure to comply can result in substantial fines by the FTC.
ASTM E84-05 (Also known as ANSI 2.5, NFPA 255, UBC 8-1 (42-1) and UL 723)
System |
Thickness |
Flame Spread Index |
Smoke Developed Index |
|
WallFoam 183M |
4” (10.2 cm) |
10 |
400 |
NFPA 286 (AC377 Appendix X)
Location |
Foam Thickness |
|
Walls |
Up to 8” (20.3 cm) |
|
Ceiling |
Up to 10” (25.4 cm) |
“A” Component contains polymeric isocyanate. “B” Component contains polyol, catalysts and blowing agents.
PROPERTY |
TEST TEMPERATURE |
ASTM TEST |
UNIT |
VALUE |
|
Viscosity – “A” Component: Viscosity – “B” Component: |
77°F (25°C) |
D-2196-68 |
cps |
180 ± 20 750 ± 50 |
|
Specific Gravity – “A” Component: Specific Gravity – “B” Component: |
77°F (25°C) |
D-1638-70 |
S.G. |
1.22 1.20 |
|
Weight/Gallon – “A” Component: Weight/Gallon – “B” Component: |
77°F (25°C) |
|
lbs/gal |
10.2 10.0 |
|
Mixing Ratio – “A” & “B” Component |
77°F (25°C) |
|
By volume |
1:1 |
|
Stability When Stored at 50°F to 70°F (10°C to 21°C) |
77°F (25°C) |
|
Months |
“A” Component: 1 year “B” Component: 6 months |
Setting |
Value |
|
Pre-Heat: Iso (A) |
110°F - 125°F (43.3°C - 51.7°C) |
|
Pre-Heat: Poly (B) |
115°F - 130°F (46.1°C - 54.4°C) |
|
Hose Heat |
115°F - 130°F (46.1°C - 54.4°C) |
|
Recommended Spray Pressure |
800 - 1,000 psi (dynamic) |
characteristic |
Value |
|
Cream Time |
0 - 1 sec |
|
Rise Time |
3 - 5 sec |
|
Tack Free Time |
3 - 5 sec |
|
Cure Time |
4 hours |
The information herein is believed to be reliable but unknown risks may be present. ALL WARRANTIES OF ANY KIND, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND THAT GOODS ARE OF MERCHANTABLE QUALITY, ARE SPECIFICALLY DISCLAIMED. See Gaco Western for information concerning its limited warranty and its availability.
Toll Free: 877-699-4226
www.gaco.com
* See product packaging for warranty details
Question or comment about a Gaco product?