You are hereHome » Insulation » WallFoam 183M
Print this Page WallFoam 183M

Gaco WallFoam
Spray Polyurethane Foam Insulation

ENERGY-EFFICIENT. STRONG. HEALTHY. GREEN. QUIET.

SMART FROM THE START

Gaco WallFoam System 183M Two Pound Closed Cell Foam


CONTRACTOR BENEFITS

  •  Sprayability. Superior formulation utilizing Transcend™ technology provides a consistent, user friendly foam with predictable yields.
  •  Less Viscous Formulation. Reduces wear and tear on equipment with less clogging of guns.
  •  Lower Odor Formula. Reduces odor in application, improving work environment.
  •  Winter and Summer Formulations. Allows you to expand your spray window in colder temperatures.
  •  Lower Spray Temperature. Easier on equipment and more comfortable to apply.

  •  Energy-Efficient. Seamless air barrier reduces uncontrolled air leakage, lowering energy costs for building owner and homeowner.
  •  Strong. Improves overall structural strength of wall and roof systems.
  •  Healthy. Reduces condensation, moisture and mold, improving occupant comfort, health and safety.
  •  Green. Higher aged R-values than conventional insulation. Reduces energy consumption, and contains no ozone-depleting chemicals. Earn up to 20 LEED credits.
  •  Quiet. Provides a quieter home with improved acoustical properties.

OWNER/SPECIFIER BENEFITS

Since 1955, Gaco Western has been manufacturing exceptional waterproofing and insulating products. This family owned company was built on three fundamental principles: superior products; sold by experts; at competitive prices. Today, Gaco Western coatings and spray foam insulation cover millions of square feet of commercial and residential buildings around the world, earning a reputation and trust in the construction industry as a producer of top-quality waterproof coatings, sealers, primers and insulation products.

 

PRODUCT DATA – Gaco WallFoam System 183M

Gaco Western WallFoam 183M is an HFC blown (zero ozone-depleting) liquid spray system that cures to a medium-density rigid polyurethane insulation material. Gaco WallFoam 183M contains polyols derived from naturally renewable oils, post-consumer recycled plastics, and pre-consumer recycled materials. Gaco WallFoam 183M does not contain CFC’s, HCFC’s or other gases harmful to the environment. This system can be sprayed on clean, dry substrates down to 35°F (2°C). Gaco WallFoam 183M is a class I fire rated foam that meets the requirements of ICC-ES AC377 Acceptance Criteria for Foam Plastic Insulation. Gaco WallFoam183M meets the requirements of AC377 Appendix X for use in attic and crawl spaces.

TECHNICAL INFORMATION

To ensure optimum performance, a minimum pass thickness of 3/4” (1.9 cm) is recommended with the maximum not to exceed 2” (5.1 cm) per pass. For typical equipment settings, consult Gaco Western’s GacoFoam Spray Guide.

PROPERTY

TEST TEMPERATURE

ASTM TEST

UNIT

VALUE

Nominal Density (Sprayed In Place):

77°F (25°C)

D-1622-03

lbs/ft3

1.8 - 2.2

R-Value (Initial)

75°F (23.9°C)

 

R at 1”

6.7

R-Value (Aged)  *See Note Below

75°F (23.9°C)  *See Note Below

C-518

R at 1”

Pending

Compressive Strength (Parallel to Rise):

77°F (25°C)

D-1621-04a

psi

32

Tensile Strength:

77°F (25°C)

D-1623

psi

64

Water Absorption:

77°F (25°C)

 

%

0.45

Water Vapor Transmission:

77°F (25°C)

E-96-05

perm-in

Pending

Dimensional Stability (7 Days):

158°F (70°C) / 95% RH

D-2126-99

% Dimen. change

4.7

Recommended Service Temperature Range:

77°F (25°C)

 

°F / °C

-40°F to 200°F
(-40°C to 93°C)

Closed Cell Content:

77°F (25°C)

D-6226-05

%

97.8

Air Permeance @ 75Pa (Infiltration/Exfiltration)

Air Permeance @ 75Pa (Infiltration/Exfiltration)

E-283-04

L/s/m2

0.000 / 0.000 (@ 1” thickness)

 

* NOTE: Federal Trade Commission regulations published in the Federal Register 16 CFR Part 460 require that R value testing of polyurethane foam insulation must be conducted on aged samples at a 75°F mean test temperature. Failure to comply can result in substantial fines by the FTC.

Surface Burning Characteristics

ASTM E84-05 (Also known as ANSI 2.5, NFPA 255, UBC 8-1 (42-1) and UL 723)

System

Thickness

Flame Spread Index

Smoke Developed Index

WallFoam 183M

4” (10.2 cm)

10

400


Room Corner Fire Testing

NFPA 286 (AC377 Appendix X)

Location

Foam Thickness

Walls

Up to 8” (20.3 cm)

Ceiling

Up to 10” (25.4 cm)

 

Typical liquid Chemical Properties

“A” Component contains polymeric isocyanate. “B” Component contains polyol, catalysts and blowing agents.

PROPERTY

TEST TEMPERATURE

ASTM TEST

UNIT

VALUE

Viscosity – “A” Component:

Viscosity – “B” Component:

77°F (25°C)

D-2196-68

cps

180 ± 20

750 ± 50

Specific Gravity – “A” Component:

Specific Gravity – “B” Component:

77°F (25°C)

D-1638-70

S.G.

1.22

1.20

Weight/Gallon – “A” Component:

Weight/Gallon – “B” Component:

77°F (25°C)

 

lbs/gal

10.2

10.0

Mixing Ratio – “A” & “B” Component

77°F (25°C)

 

By volume

1:1

Stability When Stored at 50°F to 70°F

(10°C to 21°C)

77°F (25°C)

 

Months

“A” Component: 1 year

“B” Component: 6 months



Equipment Settings

Setting

Value

Pre-Heat: Iso (A)

110°F - 125°F (43.3°C - 51.7°C)

Pre-Heat: Poly (B)

115°F - 130°F (46.1°C - 54.4°C)

Hose Heat

115°F - 130°F (46.1°C - 54.4°C)

Recommended Spray Pressure

800 - 1,000 psi (dynamic)

 

Product Characteristics

characteristic

Value

Cream Time

0 - 1 sec

Rise Time

3 - 5 sec

Tack Free Time

3 - 5 sec

Cure Time

4 hours

 

The information herein is believed to be reliable but unknown risks may be present. ALL WARRANTIES OF ANY KIND, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND THAT GOODS ARE OF MERCHANTABLE QUALITY, ARE SPECIFICALLY DISCLAIMED. See Gaco Western for information concerning its limited warranty and its availability.


Gaco Western

Toll Free: 877-699-4226
www.gaco.com

* See product packaging for warranty details

Subscribe to our Newsletter

For tips on installation, product news and more.